Sign In | Join Free | My carsrow.com
China Sinopharm Kangshun Dental(Guangdong)Co., Ltd logo
Sinopharm Kangshun Dental(Guangdong)Co., Ltd
Guangdong Baiyi Medical Technology Co.,Ltd
Verified Supplier

1 Years

Home > Dental Handpiece Repair >

Systematic Dental Handpiece Repair Quick Turnaround Dental Equipment Repair Services

Sinopharm Kangshun Dental(Guangdong)Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Systematic Dental Handpiece Repair Quick Turnaround Dental Equipment Repair Services

Brand Name : All kinds of Handpiece(Such as NSK, KaVo, W&H, COXO,etc)

Certification : ISO

Place of Origin : China

MOQ : 1 piece

Price : USD 20~250

Payment Terms : D/A, D/P, T/T, Western Union

Delivery Time : 2-8 working days after receiving payments

Packaging Details : box, 1 SET/BOX, Carton

Contact Now

Dental Handpiece Repair Quick Turnaround – Restore Your Tools Today!

Alongside producing top-tier dental mobile phones, FHJS provides expert third-party services focused on the systematic repair and maintenance of major dental mobile brands. We serve individuals, corporations, and medical facilities. Our dedicated team of technicians possesses deep expertise in both local and global brands, having accumulated significant experience in repairs, maintenance, upgrades, and operational management throughout their careers.

Systematic Dental Handpiece Repair Quick Turnaround Dental Equipment Repair Services

The repair of dental mobile phones involves many aspects. The following are some common faults:

‌The needle cannot be clamped or the needle cannot be removed‌
1. The diameter of the tail of the needle is small and does not meet the requirements.
2. Dirt blocks the chuck groove and the chuck cannot be closed.
3. The three-petal spring is worn and broken: replace the three-petal spring.
4. The needle and the clamping mechanism are rusted.

The mobile phone does not produce water or the water output is small‌:


1.The water path of the mobile phone leather line is blocked.
2.There is dirt in the water spray port of the mobile phone.
3.The internal water path of the mobile phone is blocked.

Water leakage at the connection between the handpiece and the leather line or the quick-change connector‌

1. The connection between the handpiece and the leather line is not tightened.
2. The four-hole or two-hole sealing gasket at the tail of the handpiece is aging, deformed, or damaged.
3. The front end of the quick-change connector is deformed after being dropped.
4. The small O-ring at the front end of the quick-change connector is severely worn.

The sound is abnormal, the noise becomes louder, the speed is slow, and the cutting force is too small when the handpiece is used‌

1. The head of the handpiece is injured and deformed, and the wind wheel has great resistance to operation.
2. The bearing lacks cleaning and lubrication.
3. The bearing is damaged.

Systematic Dental Handpiece Repair Quick Turnaround Dental Equipment Repair Services


In addition, for low-speed dental handpieces, if the engine does not rotate, the straight machine does not rotate when it is connected to the engine, the bending machine slips during operation, or the needle swings violently or does not rotate, etc., corresponding maintenance and processing are also required according to the specific situation.

If necessary, please leave a message for inquiry.

Systematic Dental Handpiece Repair Quick Turnaround Dental Equipment Repair Services


Product Tags:

Systematic Dental Handpiece Repair

      

Dental Handpiece Repair Quick Turnaround

      

Systematic Dental Equipment Repair Services

      
 Systematic Dental Handpiece Repair Quick Turnaround Dental Equipment Repair Services Manufactures

Systematic Dental Handpiece Repair Quick Turnaround Dental Equipment Repair Services Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sinopharm Kangshun Dental(Guangdong)Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)